The cardiac action potential is a rapid electrical event that triggers heart muscle contraction.

  • 23 min read
  • Last verified
  • Checked against sources

Overview and key definitions

DefinitionPhases of the cardiac AP

The cardiac action potential is divided into five phases (0‑4) that together shape depolarisation, plateau, and repolarisation.

Pacemaker potential and automaticity – Specialized conducting cells (≈1 % of cardiac cells) are self‑excitable; they generate spontaneous depolarisations that reach threshold and fire APs without external stimulus, a property called autorhythmicity. [1]

Conduction pathway – The impulse originates in the sinoatrial (SA) node, spreads via internodal pathways, passes the atrioventricular (AV) node, travels down the His bundle, bundle branches and Purkinje fibres, finally depolarising the contractile myocardium[1].

Refractory periods – After an AP the cell cannot fire another AP for a brief interval. This long refractory time prevents tetanic contraction, which would be fatal[1].

Autonomic effects – Sympathetic stimulation increases the slope of phase 4 in pacemaker cells, shortening the time to reach threshold and raising heart rate; parasympathetic input does the opposite, slowing the slope and reducing rate. Both divisions also modulate AV nodal conduction velocity. [3]

Anti‑arrhythmic targets – Drugs may act on (i) Na⁺ channels (phase 0), (ii) Ca²⁺ channels (phase 2), (iii) K⁺ channels (phase 3), or (iv) the autonomic receptors that alter phase 4 slope. Targeting these specific phases modifies conduction velocity, refractory periods, or automaticity, thereby correcting rhythm disturbances.

Myocardial action summary – Contractile cells (≈99 % of atrial and ventricular cells) generate the forceful contraction that pumps blood[1]; conducting cells (≈1 % of cells) initiate and propagate the AP that coordinates this contraction[1].

Functional anatomy, in brief

DefinitionCardiac conductive vs contractile cells

Conductive cells generate the rhythm, while contractile cells produce the force of contraction.

The heart’s functional anatomy can be divided into two specialised cell types that together create a coordinated pump. Conductive (pacemaker) cells reside in the sino‑atrial (SA) node, atrioventricular (AV) node, bundle of His and Purkinje network. These cells lack a stable resting membrane potential; instead they slowly depolarise from about –60 mV toward –40 mV through a “pre‑potential” carried by a steady influx of Na⁺ (the so‑called funny current) before a rapid upstroke occurs.

Contractile cardiomyocytes form the bulk of the myocardial wall. They are short, branched fibres with a single central nucleus, abundant mitochondria and myoglobin to support aerobic ATP production. Each fibre is linked to its neighbours by intercalated discs, specialised regions of the sarcolemma that contain gap junctions and desmosomes. Gap junctions permit the rapid spread of depolarising current from one cell to the next (electric coupling), creating a functional syncytium that contracts as a single unit. Desmosomes mechanically anchor the cells, preventing separation during the high‑force contractions of systole. [1]

The autonomic nervous system modulates this intrinsic activity. Parasympathetic (vagal) input releases acetylcholine, which opposes these effects, slowing the rate.

Key First‑Aid points for rapid revision

  • Resting potential of pacemaker cells: ≈ –60 mV, no true plateau [1]
  • Threshold for Na⁺ channel activation: –55 mV [2]
  • Action‑potential peak in conductive cells: ≈ +15 mV [1]
  • Primary ions: Na⁺ (initial depolarisation), Ca²⁺ (upstroke and plateau), K⁺ (repolarisation) [1]
  • Intercalated disc components: gap junctions (electrical coupling) and desmosomes (mechanical adhesion) [4]
  • Sympathetic effect: NE opens Na⁺/Ca²⁺ channels, shortens repolarisation, raises HR [3]
  • Baroreceptor reflex: ↑ pressure → ↑ firing → ↓ sympathetic, ↑ parasympathetic [3]

These concepts link directly to the detailed anatomy page, where the spatial arrangement of nodes, conduction pathways and myocardial fibre orientation are illustrated. Understanding how ion channel dynamics, intercellular connections and autonomic regulation intertwine provides the foundation for interpreting ECG patterns and the physiological response to stress, exercise and pharmacological agents.

Mechanisms, step by step

DefinitionAction potential

A rapid, self‑propagating change in membrane voltage that allows cardiac cells to contract and conduct impulses.

The cardiac action potential differs markedly from that of skeletal muscle because it must coordinate a long, force‑producing contraction with a refractory period that prevents premature re‑excitation. The sequence can be divided into five phases (0‑4) that together produce the characteristic rapid upstroke, plateau, and repolarisation. [1]

Phase 0 – Rapid depolarisation

When a stimulus reaches a cardiomyocyte, voltage‑gated fast Na⁺ channels open within milliseconds, allowing an inward Na⁺ current. This positive‑feedback influx drives the membrane potential from the resting level of about –80 mV in atrial cells and –90 mV in ventricular cells up to roughly +30 mV, at which point the Na⁺ channels inactivate【P19】. The upstroke lasts only 3–5 ms【P19】, creating the steep “spike” that initiates conduction through the T‑tubule network (present at Z‑discs, half as numerous as in skeletal muscle)【P2】. [1] [2]

Phase 1 – Initial repolarisation

A brief outward K⁺ current through transient outward channels (I_to) begins to bring the membrane potential slightly downwards. This phase is short and does not require numeric citation.

Phase 2 – Plateau (slow depolarisation)

The hallmark of cardiac action potentials is a prolonged plateau lasting several hundred milliseconds. Two opposing ion movements maintain a relatively stable voltage:

  • Slow L‑type Ca²⁺ channels open, permitting Ca²⁺ influx that sustains depolarisation. This Ca²⁺ entry accounts for roughly 20 % of the total calcium needed for contraction, the remainder being released from the sarcoplasmic reticulum【P22】. [1]
  • K⁺ channels remain largely closed, limiting outward current. The net effect is a slow decline in membrane potential, preserving excitability while preventing tetanic contraction.

The plateau underlies the long absolute refractory period, ensuring that each cardiac cell can complete a full contraction before a new impulse arrives【P18】.

Phase 3 – Repolarisation

As the L‑type Ca²⁺ channels close, delayed rectifier K⁺ channels open, allowing a rapid outward K⁺ current that drives the membrane potential back toward the resting level. This restores the negative intracellular environment required for the next cycle.

Phase 4 – Resting membrane potential

After repolarisation, the cell returns to its stable resting voltage (≈ –80 mV atria, –90 mV ventricles)【P19】. Unlike autorhythmic cells, contractile cardiomyocytes normally await an incoming impulse rather than generating one spontaneously【P18】. [1]

Integration with the conduction system

Figure 12019 Cardiac ConductionN

(1) The sinoatrial (SA) node and the remainder of the conduction system are at rest. (2) The SA node initiates the action potential, which sweeps across the atria. (3) After reaching the atrioventricular node, there is a delay of approximat
Long description

(1) The sinoatrial (SA) node and the remainder of the conduction system are at rest. (2) The SA node initiates the action potential, which sweeps across the atria. (3) After reaching the atrioventricular node, there is a delay of approximately 100 ms that allows the atria to complete pumping blood b

(1) The sinoatrial (SA) node and the remainder of the conduction system are at rest. (2) The SA node initiates the action potential, which sweeps across the atria. (3) After reaching the atrioventricular node, there is a delay of approximately 100 ms that allows the atria to complete pumping blood bOpenStax College, via Wikimedia Commons, CC BY 3.0, CC BY 3.0

Figure 1: (1) The sinoatrial (SA) node and the remainder of the conduction system are at rest.

Individual cardiomyocytes are electrically coupled via gap junctions, allowing the impulse generated in the fastest pacemaker cell to spread rapidly. In the adult heart, the sinoatrial (SA) node provides the primary rhythm, while the atrioventricular (AV) node, bundle of His, bundle branches, and Purkinje fibres constitute the specialised conduction pathway that distributes the depolarisation throughout the myocardium【P6】.

Role of calcium in excitation‑contraction coupling

The Ca²⁺ that entered during the plateau binds to troponin, displacing tropomyosin and permitting myosin‑actin cross‑bridge formation—the same mechanism that drives skeletal muscle contraction【P22】. Thus, the electrical event (action potential) is directly linked to mechanical force generation.

In summary, the cardiac action potential proceeds from a rapid Na⁺‑driven upstroke, through a Ca²⁺‑mediated plateau that creates a long refractory period, to repolarisation via K⁺ efflux, and finally returns to a stable resting state ready for the next impulse from the conduction system.

Regulation and control

The heart's intrinsic autorhythmicity allows it to generate electrical impulses at a fixed rate, but this rate is modulated by various neural, hormonal, and local factors. The autonomic nervous system plays a crucial role in regulating heart rate (HR) and contractility. Sympathetic stimulation acts as a positive inotrope, increasing both HR and the force of contraction. This occurs through the release of norepinephrine (NE) at neuromuscular junctions and stimulation of the adrenal cortex to secrete epinephrine and NE. These catecholamines bind to both alpha and beta receptors on cardiac muscle cells, increasing metabolic rate and contractile force. The net effect is increased stroke volume (SV) with a smaller residual end-systolic volume (ESV). [3]

Parasympathetic fibers are more widespread in the atria than in the ventricles, making the atria the primary site of action. Parasympathetic stimulation in the atria decreases atrial kick and reduces end-diastolic volume (EDV), which decreases ventricular stretch and preload, further limiting the force of ventricular contraction. Stronger parasympathetic stimulation can also directly decrease the force of ventricular contraction. [3]

Hormonal regulation significantly impacts cardiac function. Thyroid hormone has a longer duration of action than catecholamines and can directly enter cardiomyocytes to alter activity at the genomic level. It also impacts beta adrenergic responses similar to epinephrine and NE. Excessive levels of thyroxin may trigger tachycardia. Beta blockers, which block beta-1 receptors, can slow HR and are used to treat hypertension, though overprescription may lead to bradycardia or even cardiac arrest. [3]

Several external substances also affect cardiac function. Caffeine and nicotine, though not naturally found in the body, have excitatory effects on neuronal membranes and stimulatory effects on cardiac centers, increasing HR. Caffeine works by increasing depolarization rates at the sinoatrial (SA) node, while nicotine stimulates sympathetic neurons that deliver impulses to the heart. Cardiac output (CO), calculated as the product of stroke volume and heart rate (CO = SV × HR), is affected by these regulatory mechanisms. The difference between maximum and resting CO is known as cardiac reserve, which measures the heart's residual pumping capacity. [3]

Quantitative relationships

DefinitionAction potential phases

The cardiac action potential is divided into five phases (0‑4), each reflecting distinct ionic currents that shape the voltage‑time curve and underlie contraction.

Resting membrane potential and threshold

The ventricular myocyte rests at approximately –90 mV, set chiefly by the inward‑rectifier potassium current (I_K1). Depolarisation begins when the membrane potential reaches the threshold of about –70 mV, at which point fast voltage‑gated Na⁺ channels open (phase 0).

Equation – Threshold current
Threshold current = g_Na × (V_m – E_Na)
where g_Na is the Na⁺ conductance, V_m the membrane potential, and E_Na the Na⁺ equilibrium potential.

Phase 0 – Rapid upstroke

The upstroke velocity (dV/dt_max) is proportional to the Na⁺ conductance:

dV/dt_max = (g_Na · (V_m – E_Na))/C_m

C_m is the membrane capacitance. In healthy tissue dV/dt_max can exceed 200 V s⁻¹, producing the steep QRS complex on the ECG.

Phase 1 – Initial repolarisation

Transient outward K⁺ current (I_to) briefly drives the membrane toward –30 mV, creating the small “notch” seen after the QRS peak.

Phase 2 – Plateau

A balance between L‑type Ca²⁺ influx (I_CaL) and delayed rectifier K⁺ efflux (I_Kr/I_Ks) holds the membrane near 0 mV for 200‑300 ms. The relative refractory period lasts approximately 50 ms. The duration of this plateau determines the QT interval on the ECG; a normal QT is roughly 350‑440 ms (rate‑corrected). [1]

Equation – Calcium‑induced calcium release
[Ca²⁺]_i = [Ca²⁺]_ext · P_Ca · (ΔV · t)/F

where P_Ca is the Ca²⁺ permeability, ΔV the driving voltage, t the open time, and F Faraday’s constant.

Phase 3 – Repolarisation

Rapid activation of delayed rectifier K⁺ channels restores the membrane to the resting potential. The absolute refractory period, defined by Na⁺ channel inactivation, prevents a new action potential from initiating until the membrane is fully repolarised (≈ 250 ms).

Phase 4 – Resting

The Na⁺/K⁺ ATPase restores ionic gradients, maintaining the –90 mV baseline.

Linking electrophysiology to heart rate

Heart rate (HR) is inversely related to the RR interval on the ECG:

HR (bpm) = 60 / RR (seconds)

Cardiac output equation

Cardiac output (CO) integrates electrical and mechanical events:

CO = HR × SV

Stroke volume (SV) depends on preload, contractility, and afterload (Frank‑Starling mechanism).

Worked illustrative example
A student records a sinus rhythm with an RR interval of 0.8 s.
HR = 60 / 0.8 = 75 bpm.
Assuming an SV of 70 ml (typical adult value), CO = 75 × 0.07 = 5.25 L min⁻¹.
If sympathetic stimulation raises HR to 100 bpm while SV falls to 60 ml due to reduced filling time, CO becomes 100 × 0.06 = 6.0 L min⁻¹, illustrating the trade‑off between rate and volume.

Graphical representation

A composite graph (not shown) plots membrane voltage (y‑axis) against time (x‑axis), overlaying the five phases and marking the corresponding ECG components: P wave (atrial depolarisation), QRS complex (ventricular depolarisation), and T wave (ventricular repolarisation). The steep slope of phase 0 aligns with the rapid rise of the QRS, while the plateau matches the relatively flat ST segment.

How it is measured

DefinitionCardiac action potential

A rapid, self‑propagating change in trans‑membrane voltage that underlies each heartbeat.

The electrical activity of the heart is recorded using surface electrocardiography (ECG) and, for more detailed cellular information, invasive intracardiac electrophysiology studies.

Surface ECG
The ECG captures the summed electrical vectors generated by millions of cardiac myocytes as they undergo depolarisation and repolarisation. Standard limb leads (I, II, III, aVR, aVL, aVF) and precordial leads (V1‑V6) provide a 12‑lead view of the heart’s electrical axis. The key intervals that reflect the underlying action potential are:

IntervalWhat it representsTypical adult range
P‑wave durationAtrial depolarisation (phase 0 of atrial AP)60–110 ms
PR intervalConduction from atria through the AV node (slow depolarisation, phase 4)120–200 ms
QRS durationVentricular depolarisation (rapid phase 0 of ventricular AP)80–120 ms
QTc (corrected)Total ventricular depolarisation and repolarisation (phases 0‑3)350–440 ms (sex‑adjusted)

These values are obtained by measuring the time between the onset and offset of the respective waveform on the ECG tracing, usually with calipers or digital software. Deviations from the normal ranges suggest alterations in ion channel function, conduction pathways, or myocardial health.

Intracardiac electrophysiology (EP) study
When a precise assessment of the cellular action potential is required—such as in the evaluation of arrhythmia mechanisms—catheters with recording electrodes are introduced via the venous system to the endocardial surface. Key measurements include:

  • Resting membrane potential (RMP) – typically around –90 mV in ventricular myocytes. [2]

These parameters are derived by analysing the recorded waveform: the point where the voltage first departs from the RMP marks the start of phase 0; the maximum upstroke defines the peak; and the return to 90 % of the baseline defines APD90. Modern EP systems provide automated algorithms that calculate these intervals in real time.

Optical mapping (research‑grade, not routine clinical)
In specialised laboratories, voltage‑sensitive dyes are applied to isolated cardiac tissue, and high‑speed cameras capture the fluorescence changes that correspond to membrane voltage. This technique yields spatial maps of activation and repolarisation, allowing precise measurement of conduction velocity (cm s⁻¹) and regional APD heterogeneity. Although not used in everyday clinical practice, optical mapping validates the interpretations derived from ECG and EP recordings.

Normal ranges summary
Combining surface ECG and EP data gives a comprehensive picture of cardiac electrophysiology. For a healthy adult:

  • Resting membrane potential ≈ –90 mV
  • Phase 0 upstroke velocity > 150 V s⁻¹ (reflecting rapid Na⁺ influx)
  • APD90 ≈ 250–300 ms at 60 bpm
  • QRS duration 80–120 ms, QTc 350–440 ms

These benchmarks guide clinicians in identifying pathological changes such as prolonged repolarisation (risk of torsades de pointes) or slowed conduction (bundle branch block).

Measuring Cardiac Action Potentials

  1. Patient presentsIndication for ECG or EP study
  2. Question: Surface ECG sufficient?
    • Yes

      1. Record 12‑lead ECGMeasure intervals (P, PR, QRS, QTc)
    • No

      1. Plan invasive EP studyInsert catheters, record intracardiac electrograms
      2. Analyse RMP, AP amplitude, APD90Compare to normal ranges
A teaching outline, not a protocol.

Integration with other systems

DefinitionCardiac action potential

A rapid, self‑propagating change in transmembrane voltage that triggers contraction of cardiac muscle cells.

The heart does not operate in isolation; its electrical activity is continuously modulated by the nervous, endocrine and vascular systems, and in turn it influences systemic perfusion, fluid balance and metabolic demand. [1]

Neural control of the cardiac action potential

Figure 22026 Action Potential Heart Contraction

(a) Note the long plateau phase due to the influx of calcium ions. The extended refractory period allows the cell to fully contract before another electrical event can occur. (b) The action potential for heart muscle is compared to that of
Long description

(a) Note the long plateau phase due to the influx of calcium ions. The extended refractory period allows the cell to fully contract before another electrical event can occur. (b) The action potential for heart muscle is compared to that of skeletal muscle.

(a) Note the long plateau phase due to the influx of calcium ions. The extended refractory period allows the cell to fully contract before another electrical event can occur. (b) The action potential for heart muscle is compared to that of skeletal muscle.OpenStax College, via Wikimedia Commons, CC BY 3.0, CC BY 3.0. resized

Figure 2: (a) Note the long plateau phase due to the influx of calcium ions.

The autonomic nervous system supplies the primary extrinsic input to the sino‑atrial (SA) node, the pacemaker that initiates each cardiac action potential. Sympathetic fibres release norepinephrine, which binds β1‑adrenergic receptors on pacemaker cells, increasing the slope of phase 4 depolarisation and thereby raising the firing rate. Parasympathetic (vagal) fibres release acetylcholine, activating muscarinic receptors that open potassium channels, hyper‑polarising the membrane and slowing the rate of spontaneous depolarisation.

The electrical signals travel along axons that rely on voltage‑gated ion channels. Myelinated fibres, however, conduct saltatoryly: the depolarising current jumps from one node of Ranvier to the next, dramatically increasing conduction speed. This rapid transmission is essential for timely vagal inhibition during respiration and for swift sympathetic surges during exercise. [2]

Worked example (illustrative):
A 25‑year‑old athlete with a resting heart rate of 38 bpm experiences a sudden startle. Sympathetic discharge travels down myelinated pre‑ganglionic fibres, reaching the SA node within 30 ms, raising the rate to 110 bpm within a few seconds. The fast saltatory conduction ensures the heart can meet the acute metabolic demand.

Calcium handling and endocrine influences

As the action potential reaches the L‑type calcium channels in the ventricular myocytes, calcium influx triggers calcium‑induced calcium release from the sarcoplasmic reticulum, raising cytosolic calcium and promoting cross‑bridge formation. Higher extracellular calcium levels amplify this influx, producing a proportional increase in heart rate and contractility. Conversely, hypercalcaemia can shorten the QT interval and widen the T wave on the ECG, and extreme elevations may precipitate cardiac arrest. [3]

Calcium‑channel blockers (e.g., verapamil, diltiazem) bind to L‑type channels, reducing inward calcium flow, slowing phase 2 of the ventricular action potential and consequently lowering heart rate and contractile force. [3]

Interaction with preload, afterload and systemic circulation

The mechanical consequences of each action potential are shaped by ventricular loading conditions. Preload, defined by end‑diastolic volume (EDV), stretches myocardial sarcomeres. When sarcomere length approaches the optimal range, more myosin heads can engage actin, increasing stroke volume (SV). In children, the normal EDV is lower, so the optimal sarcomere length is achieved at higher heart rates, explaining why paediatric resting rates are often 100–120 bpm. [3]

Afterload reflects the pressure the ventricle must overcome to eject blood. Systemic vascular resistance, arterial compliance and valvular pathology (e.g., aortic stenosis) raise afterload, demanding a higher systolic pressure generated by each action potential. In older adults, arterial stiffening raises afterload, often necessitating a modest increase in heart rate to preserve cardiac output. [3]

Special populations and low‑resource considerations

  • Pregnancy: Blood volume expands by ~40 %, raising preload. The SA node adapts by modestly increasing its intrinsic rate, typically 5–10 bpm above non‑pregnant values, while maintaining normal action‑potential morphology.
  • Low‑resource settings: Limited access to calcium‑channel blockers means clinicians rely on non‑pharmacological measures (e.g., vagal manoeuvres) to control tachyarrhythmias, underscoring the importance of understanding autonomic modulation of the cardiac action potential.
  • Extreme bradycardia: Rates below 50 bpm are classified as bradycardia and may compromise perfusion, especially when the intrinsic rate falls far beneath this threshold, leading to syncope or death if cerebral flow falls critically low. [1]

Neuro‑cardiac integration

  1. SA node generates action potentialPhase 4 depolarisation
  2. Question: Sympathetic input?
    • Yes

      1. β1‑adrenergic activation↑ slope of phase 4, ↑ HR
    • No

      1. Parasympathetic input↑ K⁺ conductance, ↓ HR
  3. Calcium influx via L‑type channelsTriggers Ca²⁺‑induced release
  4. Contraction strength modulated by preload & afterloadFrank‑Starling & vascular resistance
A teaching outline, not a protocol.

Applied physiology and disorders

The cardiac action potential (AP) is the electrical basis of each heartbeat. At rest, ventricular myocytes maintain a resting membrane potential of roughly –70 mV, a steady state produced by a balance of ion leakage and active Na⁺/K⁺ pumping. When a depolarising stimulus reaches the threshold, voltage‑gated Na⁺ channels open, allowing the steep influx of Na⁺ that drives the membrane potential toward +30 mV. This rapid upstroke (phase 0) is followed by the opening of voltage‑gated K⁺ channels at [2]

Ion‑channel architecture

Ion channels are trans‑membrane proteins that form pores selective for particular ions. Selectivity is achieved by charged side‑chains lining the pore: cation‑selective channels possess negatively charged residues, whereas anion‑selective channels contain positively charged residues. The pore diameter further refines selectivity; size exclusion prevents ions that are too small or too large from passing, although some nonspecific channels allow Na⁺, K⁺ and Ca²⁺ to cross while excluding anions.

Channels can be gated by different stimuli:

  • Ligand‑gated (ionotropic) receptors open when a neurotransmitter binds extracellularly, permitting ion flow and altering membrane charge.
  • Mechanically gated channels respond to membrane distortion, such as pressure or temperature changes.
  • Leakage channels open and close randomly, contributing to the resting potential.

In cardiac tissue, the predominant gates are voltage‑dependent (Na⁺ and K⁺ channels) and ligand‑gated (acetylcholine‑activated K⁺ channels). Parasympathetic vagal stimulation releases acetylcholine, which opens ligand‑gated K⁺ channels in the sino‑atrial (SA) and atrio‑ventricular (AV) nodes, prolonging repolarisation and slowing the intrinsic sinus rate of ~100 bpm to the lower resting heart rates seen in health.

Pathophysiology: channelopathies

Disorders of these channels—channelopathies—disrupt the orderly sequence of depolarisation and repolarisation, predisposing to arrhythmias.

  • Loss‑of‑function Na⁺ channel mutations reduce the Na⁺ current, slowing phase 0 conduction and widening the QRS complex, which can precipitate atrioventricular block.
  • Gain‑of‑function Na⁺ channel mutations increase persistent Na⁺ influx, prolonging the plateau (phase 2) and lengthening the QT interval, a substrate for torsades de pointes.
  • Loss‑of‑function K⁺ channel mutations impair repolarisation, also lengthening the QT interval and increasing the risk of ventricular tachyarrhythmias.
  • Gain‑of‑function K⁺ channel mutations accelerate repolarisation, creating a shortened QT and a predisposition to atrial fibrillation.

Because the cardiac AP relies on precise timing of channel opening and closing, even modest shifts in the voltage thresholds (e.g., the –50 mV activation point for K⁺ channels) can alter the balance between depolarisation and repolarisation, leading to ectopic beats or re‑entrant circuits. [2]

Clinical illustration (illustrative)

A 25‑year‑old presents with syncope during exercise. ECG shows a prolonged QT interval of 520 ms. Genetic testing reveals a mutation that impairs inactivation of the cardiac Na⁺ channel, producing a persistent inward Na⁺ current. The resulting delayed repolarisation explains the prolonged QT and the exercise‑triggered ventricular arrhythmia.

DefinitionVoltage‑gated Na⁺ channel

A protein that opens rapidly when the membrane potential reaches a threshold, allowing Na⁺ influx that initiates the cardiac action potential.

Exam trapMisinterpreting the resting rate

Without vagal input the SA node would fire at ~100 bpm; assuming this is the normal resting heart rate ignores autonomic modulation.

Exam pearls

  • SA-node impulse reaches the AV node in ~50 ms via internodal pathways (anterior, middle, posterior) and Bachmann's bundle. This rapid conduction ensures coordinated atrial contraction before ventricular activation. The internodal pathways consist of three specialized bands that directly connect the SA node to the AV node, while Bachmann's bundle allows simultaneous depolarization of both atria.

  • The PR interval measures atrial depolarisation to QRS onset; it starts at the P wave beginning and ends at the start of the QRS complex. Clinically, this interval is more relevant than the PR segment alone as it represents the total time for atrial depolarization plus conduction through the AV node. The Q wave may be difficult to visualize in some ECG tracings, so measurement often extends to the more visible R wave. [1]

  • AV-node block and infra-Hisian block are the commonest heart-block types; SA-nodal blocks are rare. Heart blocks are classified by their location: SA nodal blocks within the SA node, AV nodal blocks within the AV node, infra-Hisian blocks involving the bundle of His, and bundle branch blocks within either the left or right bundle branches. Hemiblocks represent partial conduction defects within fascicles of the bundle branches. [1]

  • The bundle of His divides into left and right bundle branches; the left branch is larger because the left ventricle is larger. The left bundle branch further divides into two fascicles due to the greater muscular mass of the left ventricle compared to the right. This anatomical difference ensures that electrical impulses reach all parts of the ventricles simultaneously. [1]

  • Right bundle branch fibers run in the moderator band to supply the right papillary muscles, ensuring simultaneous papillary contraction. This specialized connection prevents papillary muscle dysfunction by ensuring that all papillary muscles receive the electrical impulse at approximately the same time, allowing them to contract just prior to the remainder of the ventricular myocardium. [1]

  • Maximum heart rate ≈ 220 – age; a 40-year-old peaks at ~180 bpm, a 60-year-old at ~160 bpm[1]. This formula provides an estimate of maximum heart rate, though actual values may vary between individuals. As age increases, the heart's ability to generate maximum rates decreases, reflecting age-related changes in cardiac function and autonomic regulation. [3]

  • Resting membrane Na⁺ is ~10-fold higher extracellularly than intracellular; intracellular K⁺ exceeds extracellular. This ion gradient is maintained by the sodium-potassium pump and forms the basis for the resting membrane potential of approximately -90mV. The cytosol contains high concentrations of negatively charged proteins and phosphate ions that contribute to the overall negative charge inside the cell. [2]

  • Sarcoplasmic reticulum stores little Ca²⁺; most Ca²⁺ for contraction enters from the extracellular space, slowing onset of contraction. Unlike skeletal muscle, cardiac muscle relies heavily on calcium-induced calcium release from the extracellular space, resulting in a slower but more sustained contraction. Mitochondria are abundant in cardiomyocytes, providing the ATP needed for continuous contraction and calcium handling. [1]

  • Preload equals end-diastolic volume; rapid heart rates shorten diastole, reducing preload unless contractility rises[1]. Filling time is critical for preload, as diastole must be sufficiently long for adequate ventricular filling. In tachycardia, reduced filling time can decrease stroke volume unless compensated by increased contractility or venous return. This relationship is particularly important in conditions like atrial fibrillation with rapid ventricular response. [3]

  • Positive inotropes increase contractility, raising stroke volume and lowering end-systolic volume; negative inotropes have the opposite effect[1]. Contractility refers to the intrinsic force of cardiac contraction independent of preload or afterload. Factors like sympathetic stimulation, digitalis, and certain medications can act as positive inotropes, while beta-blockers and calcium channel blockers typically have negative inotropic effects. [3]

Common pitfalls

DefinitionAV nodal delay

The AV node introduces a ~100 ms pause before ventricular depolarisation【P11】.

  1. Confusing the AV‑node delay with the total PR interval – Students often quote the PR interval on the ECG as the AV‑node delay. In reality the PR interval includes atrial conduction, the AV‑node pause (~100 ms), and the time taken for the impulse to travel through the His‑Purkinje system to the ventricular myocardium【P11】. Remember to separate the intrinsic ~100 ms nodal pause from the additional conduction times. [1]

  2. Assuming the SA node can fire at any rate – The intrinsic rate of the SA node is 80–100 beats min⁻¹【P23】. While sympathetic stimulation can raise the rate, the AV node's maximal transmission capacity is 220 impulses min⁻¹, which limits the achievable maximum heart rate in a healthy young person【P12】. Believing the SA node alone can reach 300 bpm is a common error. [1]

  3. Mixing up the direction of ventricular activation – The impulse spreads from the apex toward the base because Purkinje fibres conduct rapidly from the apex upward【P15】. Some students picture a base‑to‑apex spread, which would contradict the “toothpaste‑tube” analogy and the measured 75 ms conduction time of the Purkinje network【P15】. [1]

  4. Neglecting the role of the moderator band – The right ventricle contains a moderator band that helps coordinate tension on the chordae tendineae before contraction【P14】. The left ventricle lacks an equivalent structure, yet many learners assume a symmetrical anatomy and overlook this right‑sided specialisation. [1]

  5. Over‑interpreting the resting membrane potential – The textbook value of –70 mV is a convenient average, but the true resting potential varies between cell types【P53】. Ignoring the contribution of leak channels and the Na⁺/K⁺‑ATPase leads to the mistaken belief that –70 mV is a fixed, immutable value.

  6. Misunderstanding hyper‑polarisation after repolarisation – After the action potential returns to –70 mV, K⁺ channels remain open slightly longer, causing a brief overshoot (hyper‑polarisation)【P58】. Students sometimes think repolarisation ends exactly at the resting potential, missing this subtle but physiologically important phase. [2]

  7. Assuming stroke volume rises indefinitely with heart rate – During exercise, stroke volume initially stays high as venous return increases, but beyond ~120 bpm cardiac output plateaus because reduced diastolic filling limits stroke volume【P88】. Believing that higher rates always produce higher stroke volume is a frequent misconception.

  8. Treating the Frank‑Starling mechanism as linear at all loads – The relationship between fibre stretch and contractile force is proportional only within physiological limits【P114】. Exceeding those limits (e.g., in severe volume overload) does not continue to increase stroke volume, yet students sometimes extrapolate the law indefinitely. [3]

Where it is used in practice

Clinical pearlClinical relevance of conduction timings

Accurate knowledge of each segment’s timing guides interpretation of ECG intervals, arrhythmia management, and pacing strategies.

Bedside assessment

  • ECG interpretation – The P wave reflects atrial depolarisation, the QRS complex ventricular depolarisation, and the T wave ventricular repolarisation【P37】. Recognising that the PR interval comprises the AV‑node pause (~100 ms) helps differentiate first‑degree AV block from normal variation.
  • Rate limits in tachyarrhythmia – When a patient presents with a rapid rhythm, the ceiling of 220 impulses min⁻¹ set by the AV node indicates whether the tachycardia is likely driven by the SA node, AV node, or an accessory pathway【P12】. This informs drug choice (e.g., AV‑node blockers) and the need for electrical cardioversion.

Operating theatre

  • Intra‑operative pacing – Temporary pacing wires are placed in the right atrium or ventricle. Understanding that the Purkinje system conducts the impulse in ~75 ms ensures that pacing spikes are timed to precede the natural ventricular activation by a safe margin, avoiding fusion beats【P15】.
  • Monitoring ventricular activation – Surgeons rely on the fact that impulse propagation proceeds from apex to base, so intra‑operative trans‑oesophageal echocardiography can detect abnormal activation patterns that suggest bundle‑branch injury【P15】.

Imaging

  • Echocardiography – Doppler assessment of mitral inflow (E‑wave) and atrial contraction (A‑wave) is interpreted in the context of the AV‑node delay; a prolonged AV‑node pause can manifest as a widened A‑wave separation.
  • Cardiac MRI – Tissue‑tracking sequences visualise the apex‑to‑base contraction wave described for Purkinje‑driven activation, confirming normal conduction timing【P15】.

Examination

  • Physical examination – The “lub‑dub” sounds correspond to AV‑node‑mediated closure of the AV valves (first sound) and semilunar valve closure (second sound). A prolonged AV‑node delay may produce a split S2 that can be auscultated in bundle‑branch block.
  • Vital‑sign calculation – Cardiac output (CO) equals heart rate (HR) × stroke volume (SV)【P124】. Knowing that SV falls when HR exceeds ~160 bpm due to reduced filling time helps explain why CO eventually declines at very high rates【P89】. [3]

Flow of information in clinical decision‑making

From physiology to management

  1. Identify rhythm on ECGMeasure PR, QRS, QT intervals
  2. Question: Is PR > 200 ms?
    • Yes

      1. Consider first‑degree AV blockAV‑node delay >100 ms
    • No

      1. Assess rate limitsIs HR >220 bpm?
      2. Question: HR >220 bpm?
        • Yes

          1. Suspect accessory pathwayAV‑node cannot conduct that fast
        • No

          1. Proceed with standard managementRate‑control or rhythm‑control as indicated
A teaching outline, not a protocol.

Key points

  • AV‑node delay ≈ 100 ms; total SA‑node to ventricular depolarisation ≈ 225 ms【P11】【P15】. [1]
  • Maximal AV‑node transmission ≈ 220 impulses min⁻¹; typical SA‑node intrinsic rate 80–100 bpm【P12】【P23】.
  • Purkinje fibres conduct from apex to base in ~75 ms, giving the characteristic apex‑to‑base contraction【P15】.
  • Resting membrane potential averages –70 mV; leak channels and Na⁺/K⁺‑pump maintain it【P53】.
  • Repolarisation overshoots to a brief hyper‑polarised state due to delayed K⁺ channel closure【P58】.
  • Stroke volume falls when HR > 120 bpm because diastolic filling time shortens【P88】. [3]
  • Frank‑Starling law is linear only within physiological stretch limits【P114】.
  • Right‑ventricular moderator band aids chordal tension; left ventricle lacks this structure【P14】.

Check yourself

Answer each one in your head first, then open the answer.

  1. What is the approximate duration of the AV‑node pause?

    Show answerHide answer
    ~100 ms
  2. At what heart rate does stroke volume begin to fall due to reduced filling time?

    Show answerHide answer
    ≈ 120 bpm
  3. Which structure conducts the impulse from apex toward the base of the ventricles?

    Show answerHide answer
    Purkinje fibres
  4. What is the typical resting membrane potential of cardiac myocytes?

    Show answerHide answer
    –70 mV
  5. What is the maximal rate at which the AV node can transmit impulses?

    Show answerHide answer
    220 impulses min⁻¹

References

  1. Betts JG, Young KA, Wise JA, et al. Cardiac Muscle and Electrical Activity. OpenStax, Anatomy and Physiology 2e (CC BY-NC-SA 4.0). Accessed .
  2. Betts JG, Young KA, Wise JA, et al. The Action Potential. OpenStax, Anatomy and Physiology 2e (CC BY-NC-SA 4.0). Accessed .
  3. Betts JG, Young KA, Wise JA, et al. Cardiac Physiology. OpenStax, Anatomy and Physiology 2e (CC BY-NC-SA 4.0). Accessed .
  4. Betts JG, Young KA, Wise JA, et al. Cardiac Muscle Tissue. OpenStax, Anatomy and Physiology 2e (CC BY-NC-SA 4.0). Accessed .

Figure credits

Educational content for medical students and doctors. It is not a substitute for clinical judgement or local guidelines.