Overview and key definitions

DefinitionCardiac cycle

A complete cardiac cycle comprises one full relaxation and contraction of both atria and ventricles, lasting about 0.8 seconds**[1]**.

Phases of the cycle

The cycle begins in early diastole when all chambers are relaxed. Blood flows from the superior and inferior venae cavae and coronary sinus into the right atrium and from the pulmonary veins into the left atrium. The atrioventricular (AV) valves (tricuspid and mitral) are open, allowing passive flow into the ventricles; this passive filling accounts for roughly 70–80 % of ventricular volume**[1]**. [3]

Atrial systole follows atrial depolarisation (the P wave) and lasts about 100 ms**[1]. Atrial contraction raises atrial pressure, delivering the remaining 20–30 % of ventricular filling – the “atrial kick”[1]**. [3]

Isovolumetric contraction begins when ventricular pressure exceeds atrial pressure, closing the AV valves but before the semilunar valves open; ventricular volume remains constant.

Ventricular ejection (second phase of ventricular systole) occurs when ventricular pressure surpasses arterial pressure, opening the pulmonary and aortic semilunar valves. Stroke volume is typically 70–80 mL**[1], leaving an end‑systolic volume (ESV) of 50–60 mL after ejection from an end‑diastolic volume (EDV) of about 130 mL[1]**. [3]

Isovolumetric relaxation follows ejection; the semilunar valves close (producing the second heart sound, S2) while the AV valves remain shut. [1]

Rapid ventricular filling (late diastole) occurs when ventricular pressure falls below atrial pressure, reopening the AV valves and allowing rapid inflow. The cycle then repeats.

Pressure and volume changes

Figure 12028 Cardiac Cycle vs Electrocardiogram

Initially, both the atria and ventricles are relaxed (diastole). The P wave represents depolarization of the atria and is followed by atrial contraction (systole). Atrial systole extends until the QRS complex, at which point, the atria rela
Long description

Initially, both the atria and ventricles are relaxed (diastole). The P wave represents depolarization of the atria and is followed by atrial contraction (systole). Atrial systole extends until the QRS complex, at which point, the atria relax. The QRS complex represents depolarization of the ventricl

Initially, both the atria and ventricles are relaxed (diastole). The P wave represents depolarization of the atria and is followed by atrial contraction (systole). Atrial systole extends until the QRS complex, at which point, the atria relax. The QRS complex represents depolarization of the ventriclOpenStax College, via Wikimedia Commons, CC BY 3.0, CC BY 3.0. resized

Figure 1: Initially, both the atria and ventricles are relaxed (diastole).

During diastole, atrial pressure exceeds venous pressure, driving flow into the atria; ventricular pressure is low, permitting passive ventricular filling. Atrial contraction adds a brief pressure surge that pushes the remaining blood into the ventricles. Ventricular systole raises ventricular pressure above arterial pressure, propelling blood into the aorta and pulmonary trunk; this generates the first heart sound (S1) when the AV valves close. When ventricular pressure falls, the semilunar valves close, creating the dicrotic notch and S2**[1]**.

The pressure‑volume loop visualises these events:

  1. Filling (diastole) – volume rises from 0 mL to EDV (~130 mL) with low pressure.
  2. Isovolumetric contraction – pressure climbs sharply at constant volume.
  3. Ejection – volume falls to ESV (50–60 mL) while pressure remains high.
  4. Isovolumetric relaxation – pressure drops at constant volume back to baseline.

Valve events and heart sounds

  • AV valves (tricuspid, mitral) open in diastole, close at the onset of ventricular systole (S1).
  • Semilunar valves (pulmonary, aortic) open during ventricular ejection, close when ventricular pressure falls (S2, dicrotic notch).

Jugular venous pulse (JVP) waves

Figure 22023 ECG Tracing with Heart ContractionN

This diagram correlates an ECG tracing with the electrical and mechanical events of a heart contraction. Each segment of an ECG tracing corresponds to one event in the cardiac cycle.
Long description

This diagram correlates an ECG tracing with the electrical and mechanical events of a heart contraction. Each segment of an ECG tracing corresponds to one event in the cardiac cycle.

This diagram correlates an ECG tracing with the electrical and mechanical events of a heart contraction. Each segment of an ECG tracing corresponds to one event in the cardiac cycle.OpenStax College, via Wikimedia Commons, CC BY 3.0, CC BY 3.0. resized

Figure 2: This diagram correlates an ECG tracing with the electrical and mechanical events of a heart contraction.

The JVP mirrors right‑atrial pressure changes:

  • a‑wave: atrial contraction (atrial systole).
  • c‑wave: bulging of the tricuspid valve during isovolumetric contraction.
  • v‑wave: passive venous filling during ventricular systole when the AV valve is closed.

These waves correspond to the phases described above and provide a non‑invasive window onto cardiac timing.

Integration with the ECG

The ECG provides a temporal framework: the P wave marks atrial depolarisation, the QRS complex marks ventricular depolarisation and the onset of systole, and the T wave marks ventricular repolarisation and the start of diastole****. The sequence of mechanical events follows this electrical pattern, linking the Wiggers diagram to the ECG trace**[1]**. [2]

Functional anatomy, in brief

The cardiac muscle, or myocardium, consists of specialized cells called cardiomyocytes. Compared to skeletal muscle cells, cardiomyocytes are considerably shorter with much smaller diameters. These cells exhibit striations, which are the alternating pattern of dark A bands and light I bands attributed to the precise arrangement of myofilaments and fibrils organized in sarcomeres along the length of the cell. The contractile elements in cardiac muscle are virtually identical to those in skeletal muscle. [2]

A key structural feature of cardiac muscle cells is the presence of T (transverse) tubules that penetrate from the surface plasma membrane (sarcolemma) to the interior of the cell, allowing electrical impulses to reach the interior. Unlike skeletal muscle where T tubules are found at the junction of the A and I bands, in cardiac muscle, T tubules are only found at the Z discs. Consequently, there are one-half as many T tubules in cardiac muscle as in skeletal muscle. [2]

Cardiac muscle cells contain myoglobin, lipids, and glycogen stored within their cytoplasm. They undergo aerobic respiration, primarily metabolizing lipids and carbohydrates. The contractions in cardiac muscle are twitch-type with long refractory periods followed by brief relaxation periods. This relaxation is essential so the heart can fill with blood for the next cycle. The long refractory period prevents tetany, a condition where muscle remains involuntarily contracted, which would be incompatible with life as it would prevent the heart from pumping blood. [2]

Cardiac muscle exhibits autorhythmicity, meaning it can generate its own electrical impulse. When embryonic cardiac muscle cells are placed together, the cell with the higher inherent rate sets the pace, and the impulse spreads from the faster to the slower cell. In a fully developed adult heart, the fastest cells continue to assume control of the rate as part of the cardiac conduction system. The components of the cardiac conduction system include the sinoatrial node, the atrioventricular node, the atrioventricular bundle, the atrioventricular bundle branches, and the Purkinje cells. [2]

Action potentials in cardiac conductive cells differ from those in cardiac contractile cells. While Na+ and K+ play essential roles, Ca2+ is also critical. Cardiac conductive cells do not have a stable resting potential like skeletal muscles and neurons. They contain a series of sodium ion channels that allow a slow influx of sodium ions, causing the membrane potential to rise slowly from an initial value of −60 mV up to about –40 mV. This spontaneous depolarization (or prepotential depolarization) is followed by calcium ion channels opening, allowing Ca2+ to enter the cell and further depolarize it at a more rapid rate until it reaches approximately +15 mV. At this point, calcium ion channels close and K+ channels open, allowing K+ outflux and resulting in repolarization. [2]

When the membrane potential reaches approximately −60 mV, the K+ channels close and Na+ channels open, and the prepotential phase begins again, explaining the autorhythmicity properties of cardiac muscle. While the heart maintains a regular pace through autorhythmicity, it is also regulated by neural and endocrine controls and responds to environmental factors including electrolytes. [2] [3]

The heart receives both sympathetic and parasympathetic stimulations through a paired complex network of nerve fibers known as the cardiac plexus near the base of the heart. The cardioaccelerator center sends additional fibers, forming the cardiac nerves via sympathetic ganglia (the cervical ganglia plus superior thoracic ganglia T1–T4) to both the SA and AV nodes, plus additional fibers to the atria and ventricles. The ventricles are more richly innervated by sympathetic fibers than parasympathetic fibers. Sympathetic stimulation causes the release of norepinephrine (NE) at the neuromuscular junction of the cardiac nerves, which shortens the repolarization period, thus speeding the rate of depolarization and contraction, resulting in an increase in heart rate. NE opens chemical- or ligand-gated sodium and calcium ion channels, allowing an influx of positively charged ions. [3]

The cardiovascular center receives input from various visceral receptors including proprioreceptors, baroreceptors, and chemoreceptors, plus stimuli from the limbic system. These inputs enable the cardiovascular centers to regulate heart function precisely through cardiac reflexes. During increased physical activity, proprioreceptors in muscles, joint capsules, and tendons increase their firing rate, which the cardiac centers monitor to suppress parasympathetic stimulation and increase sympathetic stimulation as needed to increase blood flow. [3]

Their firing rates represent blood pressure, level of physical activity, and the relative distribution of blood. The cardiac centers monitor baroreceptor firing to maintain cardiac homeostasis through the baroreceptor reflex. With increased pressure and stretch, the rate of baroreceptor firing increases, and the cardiac centers decrease sympathetic stimulation and increase parasympathetic stimulation. Conversely, as pressure and stretch decrease, the rate of baroreceptor firing decreases, and the cardiac centers increase sympathetic stimulation and decrease parasympathetic stimulation. [3]

Mechanisms, step by step

DefinitionCardiac cycle

The interval from atrial contraction to ventricular relaxation, encompassing one complete heartbeat【P0】.

The Wiggers diagram integrates electrical, pressure, volume and sound events that occur during one cardiac cycle. Following the sequence from the onset of the sinus impulse to the end of ventricular relaxation provides a clear framework for understanding how the heart pumps blood.

  1. Atrial depolarisation (P wave) – The sino‑atrial (SA) node generates an automatic impulse that spreads across the atrial myocardium (autorhythmicity)【P20】. This rapid depolarisation triggers atrial contraction (atrial systole) and raises atrial pressure, pushing the remaining blood through the open atrioventricular (AV) valves into the ventricles.

  2. Isovolumetric ventricular contraction – The impulse reaches the AV node, traverses the His‑Purkinje system (bundle branches and Purkinje fibres) and arrives at ventricular contractile cells. These cells display a rapid upstroke followed by a long plateau (≈175 ms) due to slow Ca²⁺ influx【P38】【P40】. As ventricular pressure rises sharply, both AV valves close (producing the first heart sound, S₁) while the semilunar valves remain closed, so ventricular volume stays constant – the isovolumetric phase.

  3. Ventricular ejection – Once ventricular pressure exceeds aortic and pulmonary artery pressures, the semilunar valves open. Blood is expelled, causing a rapid fall in ventricular volume and a peak in arterial pressure (the systolic peak). The plateau phase continues, sustaining contraction and maintaining ejection for ≈250 ms total electrical activity【P40】.

  4. Isovolumetric relaxation – After the plateau, Ca²⁺ channels close, K⁺ channels open and repolarisation proceeds (≈75 ms)【P40】. Ventricular pressure falls below arterial pressure, causing semilunar valve closure (second heart sound, S₂). Both AV and semilunar valves are closed, so ventricular volume remains unchanged while the myocardium relaxes.

  5. Ventricular filling – As ventricular pressure drops below atrial pressure, the AV valves open. Early rapid filling occurs, followed by diastasis (slow filling) and finally atrial systole (the “atrial kick”) which contributes the last ≈20 % of stroke volume. The entire electrical event, from depolarisation to the end of repolarisation, lasts between 250 and 300 ms【P40】, matching the mechanical phases described. [3]

Refractory periods – The long plateau creates an absolute refractory period of ≈200 ms, during which no new impulse can trigger contraction, followed by a relative refractory period of ≈50 ms【P41】. This extended protection prevents premature beats that would compromise cardiac output.

Calcium’s dual role – Slow Ca²⁺ influx during the plateau supplies about 20 % of the calcium needed for contraction; the remaining 80 % is released from the sarcoplasmic reticulum【P42】. Calcium binding to troponin removes inhibition of actin‑myosin cross‑bridge formation, producing the forceful contraction that drives ejection.

Integration with haemodynamics – Stroke volume (SV) multiplied by heart rate (HR) yields cardiac output (CO)【P59】. The coordinated sequence of electrical and mechanical events ensures that each beat efficiently translates electrical energy into forward blood flow, while the long refractory periods and calcium handling preserve rhythmic stability. [3]

Regulation and control

The heart’s activity is governed by an integrated network of neural, hormonal and local mechanisms that together set heart rate (HR) and the force of contraction (inotropy). [3] [2]

DefinitionAutorhythmicity

Myocardial conducting cells generate spontaneous action potentials that set the basic rhythm of the heart.

The specialised conducting cells—most notably the sino‑atrial (SA) node—possess the highest intrinsic depolarisation rate and act as the primary pacemaker, initiating the sinus rhythm that drives each cardiac cycle. Although the SA node can fire at roughly 100 beats min⁻¹ when unmodulated, normal resting rates are lower because autonomic input continuously fine‑tunes its activity. [2]

Neural control

Central autonomic regulation originates from two paired cardiovascular centres in the medulla oblongata. The cardio‑accelerator region excites the heart via sympathetic fibres, while the cardio‑inhibitory region reduces activity through parasympathetic (vagal) fibres of cranial nerve X. At rest, a slight sympathetic tone and a dominant vagal tone maintain an autonomic baseline, analogous to skeletal‑muscle tone. [3]

Sympathetic stimulation increases HR and contractility by releasing norepinephrine (NE) onto β₁‑adrenergic receptors in both conducting and contractile cells. This shortens the pre‑potential phase, accelerates depolarisation of the SA node, and enhances calcium influx during the plateau of the contractile cell action potential, thereby increasing inotropy.

Parasympathetic (vagal) stimulation releases acetylcholine, which hyperpolarises SA‑node cells, slows the pre‑potential, and lengthens the interval between beats, producing a lower resting HR.

A reflex arc known as the Bainbridge (atrial) reflex links venous return to autonomic output. Stretch‑sensitive baroreceptors in the atrial walls fire more rapidly when the atria are filled, prompting the cardiovascular centre to increase sympathetic drive and suppress vagal tone, thus raising HR; the opposite occurs when atrial stretch diminishes. [3]

Hormonal control

Catecholamines (epinephrine and NE) released from the adrenal medulla act as potent systemic accelerators of cardiac activity, augmenting both HR and contractility in a dose‑dependent manner. Thyroid hormones exert a longer‑lasting influence: triiodothyronine (T₃) enters cardiomyocytes, modulates gene expression, and potentiates β‑adrenergic responsiveness, leading to tachycardia when levels are excessive.

Exogenous stimulants such as caffeine and nicotine also raise HR. Caffeine speeds SA‑node depolarisation, while nicotine enhances sympathetic neuronal firing to the heart, both producing a measurable increase in rate. [3]

Local (intracardiac) factors

Within the myocardium, the intrinsic properties of conducting and contractile cells shape the electrical and mechanical response. Conducting cells display a pre‑potential with a slow Na⁺ influx followed by a rapid Ca²⁺ influx and K⁺ efflux, whereas contractile cells possess a prolonged plateau phase that prolongs refractory periods and ensures coordinated contraction.

Local metabolic conditions modulate inotropy: hypoxia, acidosis and hyperkalaemia act as negative inotropic agents, diminishing calcium handling and reducing stroke volume (SV). Conversely, increased venous return raises end‑diastolic volume (preload), stretching ventricular fibres and enhancing contractile force via the Frank‑Starling mechanism, a purely mechanical, non‑neural regulator of SV. [3]

Together, these neural, hormonal and local mechanisms provide a dynamic, feedback‑driven system that matches cardiac output to the body’s instantaneous demands, preserving perfusion pressure and tissue oxygenation across a wide range of physiological states.

Quantitative relationships

The cardiac cycle involves precise quantitative relationships that are fundamental to understanding cardiac function. Stroke volume (SV) is a key measurement, normally calculated as the difference between end-diastolic volume (EDV) and end-systolic volume (ESV): SV = EDV – ESV. For a resting 70-kg individual, the mean SV is approximately 70 mL, with a normal range of 55–100 mL. Cardiac output (CO) is the product of stroke volume and heart rate (HR): CO = SV × HR. With an average resting HR of approximately 75 bpm (ranging from 60–100 bpm in some individuals), the normal CO would be around 5.25 L/min (70 mL × 75 bpm). [3]

The electrocardiogram (ECG) provides quantitative information about the heart's electrical activity. A standard electrocardiograph uses 3, 5, or 12 leads, with more leads providing greater detail. The 12-lead electrocardiograph uses 10 electrodes placed in standard locations on the patient's skin. Each component of a normal ECG tracing corresponds to important electrical events that drive cardiac contraction. [2]

These murmurs result from turbulent blood flow and can be recorded using specialized electronic stethoscopes that produce phonocardiograms or auscultograms. [1]

The Frank-Starling mechanism describes the relationship between preload and stroke volume, demonstrating that the heart automatically pumps the blood it receives. Afterload refers to the tension the ventricles must develop to pump blood against vascular resistance, with any condition increasing resistance requiring greater afterload. Factors influencing stroke volume include heart size, physical and mental condition, sex, contractility, duration of contraction, preload (EDV), and afterload. [3]

Heart rate is influenced by autonomic stimulation, with parasympathetic stimulation decreasing heart rate through acetylcholine (ACh) release, allowing heart rate to increase up to approximately 100 bpm when parasympathetic stimulation decreases. Normal blood pH falls within the range of 7.35–7.45, with values outside this range potentially affecting enzymatic reactions and heart rate. [3]

How it is measured

The cardiac cycle can be measured through various investigations that provide insights into heart function and physiology. Auscultation using a stethoscope is one of the simplest yet effective diagnostic techniques to assess the state of a patient's heart. In a normal, healthy heart, there are only two audible heart sounds: S1 and S2. S1 is created by the closing of the atrioventricular valves during ventricular contraction and is described as a "lub," while S2 is the sound of the closing of the semilunar valves during ventricular diastole and is described as a "dub". A third heart sound, S3, may occasionally be heard in healthy individuals such as youth, some athletes, and pregnant people, but is rarely heard in otherwise healthy adults. [3] [1]

Electrocardiography (ECG) provides detailed information about the cardiac cycle. This phase is divided into two distinct phases and lasts approximately 430 ms. [1]

Echocardiography and other imaging techniques allow measurement of key parameters such as stroke volume (SV) and ejection fraction. Ejection fraction is calculated by dividing SV by end-diastolic volume (EDV) and is normally expressed as a percentage. The cardiac output (CO), which is the product of heart rate (HR) multiplied by SV, can also be measured and is an important indicator of cardiac function. [3]

Heart rate monitoring is essential, as it affects cardiac output. However, when HR continues to rise above 160 bpm, CO actually decreases as SV falls faster than HR increases. Therefore, the target heart rate range for aerobic exercise is between 120 and 160 bpm to maintain optimal cardiac output. [3]

Integration with other systems

The cardiac cycle is not an isolated mechanical event; it is continuously modulated by the autonomic nervous system, the respiratory system, and the endocrine system to match cardiac output to the metabolic demands of the body. However, in daily life, the balance between sympathetic and parasympathetic tone adjusts this intrinsic rate. Sympathetic stimulat [2]

The respiratory system also integrates with the cardiac cycle. During inhalation, blood flow into the right side of the heart increases, which can amplify right-sided heart murmurs; during expiration, flow into the left side is partially restricted, amplifying left-sided murmurs. This is why clinicians ask patients to breathe deeply during auscultation—not only to listen to airflow but also to bring out murmurs.

Changes with heart rate are particularly important. As heart rate rises, the duration of diastole shortens more than systole, reducing the time available for ventricular filling. Initially, as heart rate increases from resting to approximately 120 bpm, cardiac output rises because the increased rate compensates for any slight reduction in filling. However, as heart rate continues to climb, stroke volume gradually decreases due to reduced filling time, and cardiac output eventually falls when the increasing rate can no longer compensate for the decreasing stroke volume. This explains why tachycardia beyond a certain point is inefficient and can compromise tissue perfusion. [3]

The Frank-Starling mechanism links the cardiac cycle to venous return and preload. Within physiological limits, the force of heart contraction is directly proportional to the initial length of the ventricular muscle fibres—that is, the more the ventricles are stretched by incoming blood, the more forceful the contraction. During exercise, increased venous return initially raises stroke volume, but at very high heart rates, the shortened diastole limits this compensatory stretch. [3]

The conduction system also shows intrinsic rate hierarchies that integrate with autonomic control. Without the SA node, the AV node would generate a heart rate of 40–60 beats per minute; if the AV node were blocked, the atrioventricular bundle would fire at 30–40 impulses per minute, the bundle branches at 20–30, and the Purkinje fibres at 15–20. These lower rates are insufficient for normal activity, which is why an artificial pacemaker may be implanted to restore a junctional rhythm to full sinus rhythm. The total time from SA node initiation to ventricular depolarisation is approximately 225 ms, with the impulse reaching all ventricular muscle cells in about 75 ms via the Purkinje fibres. [2]

Applied physiology and disorders

The cycle is driven by the coordinated propagation of action potentials through the conduction system, and any disorder that alters this sequence produces characteristic clinical and haemodynamic consequences.

Heart failure is the prototypical disorder of the cardiac cycle. It arises when the heart cannot pump sufficient blood to meet metabolic demands, often due to impaired contractility (systolic failure) or impaired ventricular filling (diastolic failure). In systolic failure, the ejection fraction falls below the normal range of approximately 55–70%; the ventricle fails to empty adequately, leaving an increased end-systolic volume. This raises end-diastolic pressure, which is transmitted backward to the atria and pulmonary or systemic venous circulation, producing pulmonary oedema or peripheral oedema. In diastolic failure, ventricular compliance is reduced (e.g. from hypertrophy or fibrosis), so filling pressures rise steeply even with normal ejection fraction. The Frank–Starling mechanism, which normally matches stroke volume to venous return, becomes blunted because the failing ventricle operates on a flattened, descending limb of the length–tension curve.

Valvular disorders directly distort the pressure–volume relationships of the cycle. Aortic stenosis imposes a pressure overload on the left ventricle: the ventricle must generate very high systolic pressures (often >200 mmHg) to overcome the narrowed orifice, leading to concentric hypertrophy and eventually diastolic dysfunction. Aortic regurgitation, by contrast, produces volume overload: blood leaks back into the left ventricle during diastole, increasing end-diastolic volume and stroke work, causing eccentric hypertrophy. Mitral stenosis impedes left atrial emptying, raising left atrial pressure and causing pulmonary congestion, while mitral regurgitation allows systolic reflux of blood into the left atrium, reducing forward stroke volume and causing atrial enlargement.

Arrhythmias disrupt the timing of the cycle. Atrial fibrillation abolishes the "atrial kick" — the atrial contraction that normally contributes approximately 15–25% of ventricular filling. This reduces stroke volume, particularly in patients with stiff ventricles. Ventricular tachycardia or fibrillation eliminates coordinated ventricular contraction entirely, so no effective cardiac output occurs, leading to cardiac arrest. Heart block (e.g. complete AV block) dissociates atrial and ventricular rhythms; the ventricles then beat at their intrinsic escape rate of 20–40 beats per minute, which is often inadequate for perfusion.

Calcium homeostasis is critical because calcium ions couple excitation to contraction. High calcium levels (hypercalcaemia) increase heart rate and contractility, shorten the QT interval (the time from ventricular depolarisation to repolarisation) and widen the T wave; extremely high levels may induce cardiac arrest. Conversely, hypocalcaemia prolongs the QT interval and reduces contractility. Calcium channel blockers (e.g. verapamil, diltiazem) slow the heart rate by blocking the inward movement of calcium ions through L-type channels in nodal tissue, and are used to treat tachyarrhythmias and hypertension. [3]

Ischaemic heart disease impairs the cycle regionally. Coronary occlusion causes a segment of myocardium to lose contractile function within seconds; the affected wall may bulge paradoxically during systole (dyskinesia), reducing global ejection fraction. If the papillary muscles are ischaemic, mitral regurgitation may ensue, further compromising forward flow.

Pericardial disease restricts filling. Cardiac tamponade compresses all four chambers, raising diastolic pressures equally and reducing stroke volume; pulsus paradoxus (an exaggerated inspiratory fall in systolic blood pressure >10 mmHg) reflects the enhanced ventricular interdependence. Constrictive pericarditis produces a "dip-and-plateau" pattern in ventricular pressure tracings, with rapid early filling followed by an abrupt halt.

Exam pearls

Common pitfalls

Students frequently struggle with the cardiac cycle because they conflate electrical events with mechanical actions or misinterpret the pressure-volume relationships. A primary error is assuming that ventricular contraction begins immediately when the QRS complex appears on an electrocardiogram. In reality, the electrical depolarization is the trigger for muscular contraction, but there is a brief mechanical delay. The wave of depolarization begins in the right atrium and spreads across the superior portions of both atria before moving down through the contractile cells. This electrical signal initiates the contraction, but the actual rise in intraventricular pressure takes time. Consequently, students often fail to recognize the isovolumic contraction phase. During this initial phase of ventricular systole, the ventricular muscles contract and pressure rises, but it is not yet high enough to open the semilunar valves. Because the atrioventricular valves have already closed due to the pressure rise, no blood is ejected, and the volume remains constant. [2]

Another common mistake is misunderstanding the dicrotic notch. Many students believe this small dip in the blood pressure tracing represents a secondary contraction of the ventricle. In fact, the dicrotic notch occurs during the early phase of ventricular diastole when the ventricular muscle relaxes and pressure falls below that in the pulmonary trunk and aorta. This pressure reversal causes blood to flow back toward the heart, forcing the semilunar valves to close to prevent backflow. Since the atrioventricular valves remain closed at this point, the volume of blood in the ventricle does not change, marking the isovolumic ventricular relaxation phase. Confusing this passive closure with active contraction leads to errors in interpreting pressure tracings.

Students also frequently misinterpret the resting membrane potentials of cardiac cells. They often assume that all cardiac cells have the same resting potential. However, contractile cells demonstrate a much more stable resting phase than conductive cells, with potentials of approximately −80 mV in atrial cells and −90 mV in ventricular cells. The rapid depolarization period, which lasts only 3–5 ms, is driven by the opening of voltage-gated sodium channels, raising the membrane potential to approximately +30 mV. A critical error is overlooking the plateau phase, where the membrane potential declines slowly due to the opening of slow calcium channels and the limited opening of potassium channels. This plateau is essential for maintaining contraction and preventing tetanus in the heart.

Misreading the ECG intervals is another significant pitfall. Students often fail to link the PR interval to conduction delays. A delay in the passage of the impulse from the SA node to the AV node is visible in the PR interval. In first-degree AV block, this delay is recognized as an abnormally long PR interval. In second-degree block, some P waves are not followed by a QRS complex, indicating incomplete conduction. In third-degree block, there is no correlation between atrial activity and ventricular activity. Students must understand that the AV node can assume the role of pacemaker at 40–60 contractions per minute if the SA node fails, which is adequate to maintain consciousness.

Finally, students often confuse the effects of electrolyte imbalances on heart rate. They may assume that all electrolyte disturbances cause tachycardia. In reality, the relationship is complex. Potassium has greater clinical significance than sodium. Hypokalemia leads to arrhythmias, whereas hyperkalemia causes the heart to become weak and flaccid, ultimately leading to failure. Severe hyponatremia leads to bradycardia and other arrhythmias, while severely high hypernatremia may lead to fibrillation. Understanding these specific effects is crucial for interpreting clinical scenarios.

Ventricular Systole and Diastole

  1. Atrial DepolarizationP wave on ECG
  2. Ventricular DepolarizationQRS complex on ECG
  3. Isovolumic ContractionPressure rises, AV valves close, volume constant
  4. Question: Pressure exceeds aortic/pulmonary pressure?
    • Yes

      1. Ventricular EjectionSemilunar valves open, blood ejected
    • No

      1. Continued ContractionPressure continues to rise
  5. Pressure falls below aortic/pulmonary pressureSemilunar valves close, dicrotic notch
  6. Isovolumic RelaxationAV valves remain closed, volume constant
  7. Question: Ventricular pressure < atrial pressure?
    • Yes

      1. Ventricular FillingAV valves open, ventricles fill
    • No

      1. Continued RelaxationPressure continues to fall
A teaching outline of the mechanical phases.

Where it is used in practice

Knowledge of the cardiac cycle is fundamental to clinical practice across multiple settings. At the bedside, understanding the relationship between electrical and mechanical events allows clinicians to interpret heart sounds accurately. The first heart sound (S1) corresponds to the closure of the atrioventricular valves during the beginning of ventricular systole, while the second heart sound (S2) results from the closure of the semilunar valves during early ventricular diastole. These sounds provide critical information about valve function and timing. For instance, a split S2 may indicate delayed closure of the pulmonary valve, which can occur in right bundle branch block or pulmonary hypertension.

In the operating theatre, cardiac cycle knowledge guides surgical interventions, particularly during cardiac procedures. Surgeons must coordinate their actions with the cardiac cycle to minimize bleeding and optimize visualization. For example, during aortic valve replacement, the surgeon may place a cross-clamp during diastole to reduce the risk of coronary artery occlusion. Understanding the isovolumic phases is crucial here, as these represent periods when no blood is being ejected, making them potentially safer moments for certain interventions.

Cardiac cycle knowledge is essential in interpreting various imaging modalities. Echocardiography directly visualizes the mechanical events of the cardiac cycle, allowing assessment of chamber sizes, valve function, and contractility. The ability to recognize isovolumic contraction and relaxation phases helps identify abnormalities in ventricular function. In cardiac MRI, the timing of image acquisition relative to the cardiac cycle is critical for obtaining clear images, particularly when using cine techniques to visualize blood flow and wall motion.

In clinical practice, understanding the cardiac cycle is vital for managing patients with heart failure. In healthy young individuals, heart rate may increase to 150 bpm during exercise, and stroke volume can increase from 70 to approximately 130 mL, increasing cardiac output to approximately 19.5 L/min, 4–5 times the resting rate. In heart failure patients, these normal adaptive responses are impaired. Clinicians use this knowledge to prescribe medications that affect the cardiac cycle, such as beta-blockers that reduce heart rate and digitalis, which lowers heart rate while increasing the strength of contraction by blocking the sequestering of calcium ions into the sarcoplasmic reticulum. [3]

During examinations, medical students must demonstrate a thorough understanding of the cardiac cycle to answer questions correctly. Questions often test the relationship between ECG findings and mechanical events, such as identifying when the semilunar valves open relative to the QRS complex. Students may be asked to calculate cardiac output using the formula CO = HR × SV, with normal values of approximately 5 L/min at rest. Understanding how cardiac output can increase 7-8 times in top cardiovascular athletes is frequently tested. Additionally, questions may focus on recognizing arrhythmias on ECG, such as identifying first-degree AV block as an abnormally long PR interval or third-degree block as no correlation between P waves and QRS complexes.

Key points

  • The cardiac cycle consists of electrical and mechanical events that must be understood separately but recognized as interconnected
  • Isovolumic contraction occurs when ventricular pressure rises but is insufficient to open semilunar valves [1]
  • The dicrotic notch represents semilunar valve closure during early ventricular diastole when pressure falls below aortic/pulmonary pressure [1]
  • Contractile cells have resting potentials of -80 mV (atria) and -90 mV (ventricles) with a rapid depolarization lasting 3-5 ms [2]
  • AV blocks are classified by degree: first-degree shows prolonged PR interval, second-degree shows some P waves without QRS, third-degree shows no correlation between P waves and QRS complexes [2]
  • Cardiac output can increase from 5 L/min at rest to 19.5 L/min during exercise in healthy individuals [3]
  • Electrolyte imbalances have specific effects: hyperkalemia causes weakness and failure, hypokalemia causes arrhythmias, severe hyponatremia causes bradycardia [3]
  • Digitalis acts as a positive inotropic agent by blocking calcium sequestration, increasing intracellular calcium and contractility [3]

Check yourself

Answer each one in your head first, then open the answer.

  1. What phase of ventricular systole occurs when pressure rises but semilunar valves remain closed?

    Show answerHide answer
    Isovolumic contraction
  2. What ECG finding corresponds to third-degree AV block?

    Show answerHide answer
    No correlation between P waves and QRS complexes
  3. What is the approximate maximum cardiac output in L/min that healthy young individuals can achieve during exercise?

    Show answerHide answer
    19.5 L/min
  4. What electrolyte imbalance causes the heart to become weak and flaccid?

    Show answerHide answer
    Hyperkalemia
  5. What is the normal pacemaker rate of the AV node in beats per minute?

    Show answerHide answer
    40-60 bpm

References

  1. Betts JG, Young KA, Wise JA, et al. Cardiac Cycle. OpenStax, Anatomy and Physiology 2e (CC BY-NC-SA 4.0). Accessed .
  2. Betts JG, Young KA, Wise JA, et al. Cardiac Muscle and Electrical Activity. OpenStax, Anatomy and Physiology 2e (CC BY-NC-SA 4.0). Accessed .
  3. Betts JG, Young KA, Wise JA, et al. Cardiac Physiology. OpenStax, Anatomy and Physiology 2e (CC BY-NC-SA 4.0). Accessed .

Figure credits

Educational content for medical students and doctors. It is not a substitute for clinical judgement or local guidelines.