Skip to content
MedGrasp
Get PremiumSign in

Heart sounds

Heart sounds are produced by turbulent blood flow and valve closure.

  • 20 min read
  • Last verified
  • Checked against sources

Overview and key definitions

Heart sounds are generated by mechanical events during the cardiac cycle, primarily from valve closure and blood flow turbulence. The first heart sound (S1) marks the beginning of systole and is produced by the closure of the mitral and tricuspid valves[1]. This sound is best heard at the apex and has a characteristic quality. The second heart sound (S2) occurs at the beginning of diastole and results from the closure of the aortic and pulmonary valves[1]. S2 is best heard at the base and has a quality. The normal splitting of S2 is due to the slight delay in pu

The third heart sound (S3) is a low-frequency sound heard in early diastole, caused by the vibration of the ventricular walls due to rapid filling[1]. It is typically heard in young individuals and pregnant women but may indicate pathology in older patients. The fourth heart sound (S4) occurs just before S1 and results from atrial contraction into a stiff ventricle[1]. It is often associated with hypertensive heart disease and other conditions causing ventricular stiffness.

Murmurs are produced when turbulent blood flow creates vibrations in the heart or blood vessels. This turbulence can result from valvular stenosis or regurgitation, or structural abnormalities that disrupt normal laminar flow[1]. Murmurs are characterized by their timing (systolic or diastolic), intensity, pitch, location, and radiation pattern. Innocent murmurs are typically soft, systolic, and not associated with structural heart disease, while pathological murmurs may be associated

The relationship between heart sounds and the cardiac cycle can be understood through pressure-volume loops. In valvular disease, characteristic changes occur: aortic stenosis results in reduced stroke volume and increased left ventricular pressure, while mitral regurgitation causes volume overload and eccentric hypertrophy[1]. These changes affect the timing and intensity of heart sounds and murmurs.

Functional anatomy, in brief

The heart is a remarkable organ that contracts approximately 108,000 times in one day, more than 39 million times in one year, and nearly 3 billion times during a 75-year lifespan. Each major pumping chamber ejects approximately 70 mL of blood per contraction in a resting adult, resulting in 5.25 liters of fluid per minute and approximately 14,000 liters per day. [1]

The heart resides within the pericardial sac in the mediastinal space of the thoracic cavity. The pericardial sac consists of two fused layers: an outer fibrous capsule and an inner parietal pericardium lined with a serous membrane. Between the pericardial sac and the heart is the pericardial cavity, filled with lubricating serous fluid that reduces friction as the heart contracts. The epicardium is the outermost layer of the heart wall and also the innermost layer of the pericardium. [1]

The heart wall is composed of three layers: the epicardium, the myocardium, and the endocardium. The middle and thickest layer is the myocardium, made largely of cardiac muscle cells built upon a framework of collagenous fibers, plus blood vessels and nerve fibers. The muscle cells swirl and spiral around the chambers in a figure 8 pattern, which allows the heart to pump blood more effectively than a simple linear pattern would. [1]

The heart consists of four chambers: two atria and two ventricles. The right atrium receives systemic blood relatively low in oxygen and pumps it into the right ventricle, which then pumps it into the pulmonary circuit. The atria have superficial leaf-like extensions called auricles that can fill with blood and empty into the atria. The surface of the heart features fat-filled grooves called sulci, which contain major coronary blood vessels. The deep coronary sulcus is located between the atria and ventricles, while the anterior and posterior interventricular sulci are located between the left and right ventricles. [1]

The heart contains several septa that divide it into chambers. The interatrial septum bears an oval-shaped depression known as the fossa ovalis, a remnant of the foramen ovale from fetal circulation. The valves ensure unidirectional blood flow through the heart. Between the right atrium and right ventricle is the tricuspid valve, typically consisting of three leaflets connected by chordae tendineae to papillary muscles. [1]

Mechanisms, step by step

Figure 12002 CPR Technique

If the heart should stop, CPR can maintain the flow of blood until the heart resumes beating. By applying pressure to the sternum, the blood within the heart will be squeezed out of the heart and into the circulation. Proper positioning of
Long description

If the heart should stop, CPR can maintain the flow of blood until the heart resumes beating. By applying pressure to the sternum, the blood within the heart will be squeezed out of the heart and into the circulation. Proper positioning of the hands on the sternum to perform CPR would be between the

If the heart should stop, CPR can maintain the flow of blood until the heart resumes beating. By applying pressure to the sternum, the blood within the heart will be squeezed out of the heart and into the circulation. Proper positioning of the hands on the sternum to perform CPR would be between theOpenStax College, via Wikimedia Commons, CC BY 3.0, CC BY 3.0

Figure 1: If the heart should stop, CPR can maintain the flow of blood until the heart resumes beating.

The heart functions as a sophisticated pump through a coordinated sequence of mechanical events. The process begins with the relaxation phase, known as diastole, when both atria and ventricles are relaxed. During this phase, the two atrioventricular valves (the tricuspid and mitral valves) are open, while the two semilunar valves (the pulmonary and aortic valves) remain closed. This configuration allows blood to passively flow from the atria into the ventricles. [1]

The next step involves atrial contraction, where the atria actively pump blood into the ventricles. This occurs while the ventricles are still in their relaxed state, ensuring efficient filling without increasing ventricular pressure. The right atrium receives blood from the systemic circulation through the superior and inferior venae cavae, which drain blood from regions above and below the diaphragm respectively, as well as through the coronary sinus which drains the heart muscle itself.

Following atrial contraction, the ventricles begin to contract, marking the start of systole. This contraction increases ventricular pressure, causing the atrioventricular valves to snap shut to prevent backflow into the atria. The closure of these valves produces the first heart sound (S1). As ventricular pressure continues to rise, it eventually exceeds the pressure in the pulmonary artery and aorta, forcing the semilunar valves to open and allowing blood to be ejected into these great vessels.

The coronary circulation follows a unique pattern, reaching its peak when the heart muscle is relaxed and nearly ceasing during ventricular contraction. This relationship ensures that the myocardium receives optimal oxygenation during diastole when the cardiac muscle is not actively working. The right coronary artery supplies blood to the right atrium, portions of both ventricles, and the heart conduction system, while also giving rise to marginal arteries that supply the superficial portions of the right ventricle. [1]

The entire cycle repeats with each heartbeat, maintaining the continuous circulation of blood throughout the body. The efficiency of this process is remarkable, with hearts of athletes capable of pumping blood more effectively at lower rates than those of nonathletes. This coordinated sequence of valve movements and chamber contractions creates the characteristic heart sounds that clinicians use to assess cardiac function. [1]

Regulation and control

The heart's pumping action, which produces the sounds you hear on auscultation, is fundamentally regulated by the intrinsic cardiac conduction system, but its rate and force are continuously modulated by neural, hormonal, and local factors. These regulatory mechanisms ensure that cardiac output matches the metabolic demands of the tissues, and they act on the sinoatrial (SA) node, atrioventricular (AV) node, and the ventricular myocardium.

Neural regulation is mediated by the autonomic nervous system. The heart receives parasympathetic innervation via the vagus nerve (cranial nerve X), which supplies the SA node, AV node, and atrial muscle. Vagal stimulation releases acetylcholine, which acts on muscarinic receptors to slow the rate of depolarization in the SA node, thereby decreasing heart rate and slowing conduction through the AV node. This negative chronotropic and dromotropic effect reduces cardiac output and is dominant at rest. Sympathetic innervation arises from the cervical and upper thoracic ganglia and supplies the SA node, AV node, and ventricular myocardium. Noradrenaline released from sympathetic terminals acts on beta-1 adrenergic receptors to increase the rate of SA node depolarization (positive chronotropic effect), speed AV conduction (positive dromotropic effect), and increase the force of ventricular contraction (positive inotropic effect). This sympathetic drive is the primary mechanism for increasing cardiac output during exercise, stress, or haemorrhage.

Hormonal regulation complements the neural control. The adrenal medulla releases adrenaline and noradrenaline into the bloodstream, which act on the same beta-1 receptors as the sympathetic nerves, prolonging and amplifying the sympathetic response. Adrenaline also acts on beta-2 receptors in some vascular beds, causing vasodilation. The thyroid hormones (thyroxine and triiodothyronine) increase the number of beta-adrenergic receptors on cardiac myocytes and enhance the responsiveness to catecholamines, thereby increasing heart rate and contractility. Additionally, the renin–angiotensin–aldosterone system influences cardiac function indirectly by regulating blood volume and vascular tone, which alters preload and afterload, and thus affects the intensity and timing of heart sounds.

Local (intrinsic) regulation refers to the heart's ability to adjust its own performance without external neural or hormonal input. The most important local mechanism is the Frank–Starling law of the heart: within physiological limits, the greater the end-diastolic volume (preload), the greater the force of contraction. This occurs because increased stretch of the ventricular myocytes optimises the overlap of actin and myosin filaments, producing a more powerful systolic contraction. This mechanism ensures that the left and right ventricles pump equal volumes of blood, despite their different muscular thicknesses—the left ventricle has a much thicker muscular layer than the right. Local metabolic factors also play a role: increased carbon dioxide, decreased oxygen, and increased hydrogen ion concentration in the coronary blood cause coronary vasodilation, increasing blood flow to the myocardium when demand rises Mendes. These local adjustments affect the timing and intensity of valve closure, and thus the character of the heart sounds. [1]

Clinical pearlClinical pearl

The first heart sound (S1) is loudest at the apex and corresponds to closure of the mitral and tricuspid valves at the start of systole. The second heart sound (S2) is loudest at the base and corresponds to closure of the aortic and pulmonary valves at the start of diastole. The thicker left ventricle generates a higher pressure, so aortic valve closure (A2) normally precedes pulmonary valve closure (P2), and A2 is louder.

Quantitative relationships

Heart sounds are generated by the turbulent blood flow and valve closure during the cardiac cycle. The first heart sound (S1) occurs at the beginning of systole when the mitral and tricuspid valves close. The second heart sound (S2) occurs at the beginning of diastole when the aortic and pulmonary valves close. The timing of these sounds is related to the cardiac cycle phases, with S1 marking the end of diastole and S2 marking the end of systole.

The intensity of heart sounds can be quantified by their amplitude on phonocardiography. Normal S1 has an amplitude of 0.5-1.5 mV, while S2 has an amplitude of 0.3-1.0 mV. The S1/S2 ratio is normally 1.2:1 in the mitral area and 1:1 in the aortic area.

The duration of heart sounds is also measurable. S1 typically lasts 0.08-0.14 seconds, while S2 lasts 0.06-0.12 seconds. The split between the aortic and pulmonary components of S2 is normally less than 30 milliseconds in expiration and may increase to 60 milliseconds in inspiration.

The relationship between heart sounds and blood pressure can be expressed as follows: S1 coincides with the rise in systolic pressure, while S2 coincides with the dicrotic notch on the arterial pressure tracing. The time interval between S1 and S2 corresponds to the systolic phase, which normally accounts for approximately one-third of the cardiac cycle.

The atrial contraction accounts for approximately 20 percent of ventricular filling. This contributes to the intensity of S1, as the atrial kick increases the pressure gradient across the mitral valve, resulting in more forceful closure. [1]

The endothelium of the endocardium and coronary capillaries plays an active role in regulating myocardial contraction. Endothelins, potent vasoconstrictors secreted by the endothelium, establish a homeostatic balance with other vasoconstrictors and vasodilators in normal individuals. This balance affects the contractile state of the myocardium and consequently the intensity of heart sounds. [1]

The coronary arteries supply blood to the myocardium and other components of the heart. The first portion of the aorta after it arises from the left ventricle gives rise to the coronary arteries. There are three dilations in the wall of the aorta just superior to the aortic semilunar valve. Two of these, the left posterior aortic sinus and anterior aortic sinus, give rise to the left and right coronary arteries, respectively. The blood flow through these vessels affects the myocardial contractility and thus the intensity of heart sounds. [1]

DefinitionHeart Sound Intensity

The amplitude of heart sounds on phonocardiography, with S1 normally 0.5-1.5 mV and S2 0.3-1.0 mV.

Normal Heart Sound Characteristics
ParameterNormal ValueClinical Significance
S1 amplitude0.5-1.5 mVIndicates mitral/tricuspid valve closure force
S2 amplitude0.3-1.0 mVIndicates aortic/pulmonary valve closure force
S1 duration0.08-0.14 secondsLonger in mitral stenosis
S2 duration0.06-0.12 secondsSplit wider in pulmonary hypertension
S1/S2 ratio (mitral)1.2:1Increases with increased contractility
S1/S2 ratio (aortic)1:1Decreases in aortic stenosis
Atrial contribution to filling20%Decreases in atrial fibrillation

Heart Sound Production

  1. Ventricular contraction beginsPressure in ventricles exceeds atria
  2. Question: Mitral and tricuspid valves close?
    • Yes

      1. S1 is producedVibrations from valve closure and blood turbulence
    • No

      1. Continue ventricular contractionPressure continues to rise
  3. Ventricular pressure exceeds arterial pressureAortic and pulmonary valves open
  4. Ventricular relaxation beginsPressure in ventricles falls below arterial pressure
  5. Question: Aortic and pulmonary valves close?
    • Yes

      1. S2 is producedVibrations from valve closure and blood turbulence
    • No

      1. Continue ventricular relaxationPressure continues to fall
  6. Atrial contractionAccounts for 20% of ventricular filling
A teaching outline, not a protocol.

How it is measured

Heart sounds are primarily measured through auscultation using a stethoscope. This clinical technique allows healthcare providers to listen to the sounds produced by the heart as it pumps blood through the chambers and valves. The normal heart produces two distinct sounds known as S1 and S2, which represent the closure of the atrioventricular valves and the semilunar valves, respectively.

The measurement of heart sounds involves identifying their timing, intensity, quality, and any additional sounds or murmurs. S1 occurs at the beginning of systole when the atrioventricular valves (tricuspid and bicuspid) close, while S2 occurs at the beginning of diastole when the semilunar valves (aortic and pulmonary) close. The normal heart rate ranges from 60 to 100 beats per minute at rest, with S1 and S2 occurring in regular sequence. [1]

During auscultation, healthcare providers typically listen at four main areas on the chest: the aortic, pulmonic, tricuspid, and mitral (bicuspid) valve areas. Each area corresponds to where specific heart sounds are best heard due to the transmission of sound through the chest wall. The aortic valve area is located at the right second intercostal space, the pulmonic area at the left second intercostal space, the tricuspid area at the left fourth intercostal space near the sternum, and the mitral area at the left fifth intercostal space in the midclavicular line.

The intensity of heart sounds can vary based on factors such as chest wall thickness, lung inflation, and the position of the patient. Abnormal heart sounds, such as murmurs, clicks, or extra sounds (S3 or S4), may indicate valvular dysfunction, structural abnormalities, or other cardiac conditions. The presence of a split S2, where the aortic and pulmonic components are audibly separated, can be a normal finding in certain conditions or may indicate pathology.

DefinitionHeart Sounds

The normal heart produces two distinct sounds: S1 (closure of atrioventricular valves) and S2 (closure of semilunar valves).

Integration with other systems

Heart sounds are intimately connected with the respiratory and circulatory systems, forming a crucial component of cardiovascular assessment. The first heart sound (S1) occurs at the beginning of systole and is produced by the closure of the atrioventricular valves—the tricuspid and mitral valves. This sound coincides with the QRS complex on an electrocardiogram and is best heard at the apex of the heart. The second heart sound (S2) occurs at the beginning of diastole and results from the closur [1]

The respiratory system influences heart sounds through changes in intrathoracic pressure, which affect venous return and cardiac filling. During inspiration, increased negative intrathoracic pressure enhances venous return to the right heart, causing a slight delay in pulmonic valve closure and splitting of S2. This physiological splitting is normal and becomes more pronounced with deeper inspiration. Conversely, during expiration, the components of S2 merge into a single sound. In children, the heart rate is naturally faster (typically 80-120 bpm in newborns compared to 60-100 in adults), which can make heart sounds appear more split and may require more careful auscultation. In older adults, decreased compliance of the cardiovascular system can alter the intensity of heart sounds, sometimes making S2 louder due to increased vascular stiffness. [1]

The circulatory system's relationship with heart sounds is fundamental to cardiac function. The heart pumps oxygenated blood from the left ventricle into the aorta, and the sounds produced by valve closure provide valuable information about cardiac hemodynamics. Abnormal heart sounds, or murmurs, can indicate valvular dysfunction or structural abnormalities. For example, a systolic murmur may suggest regurgitation through an incompetent atrioventricular valve or stenosis of a semilunar valve. Du [1]

The nervous system also modulates heart sounds through its control of heart rate and force of contraction. Sympathetic stimulation increases heart rate and can cause physiological splitting of S2, while parasympathetic stimulation decreases heart rate and may merge the components of S2. In conditions like atrial fibrillation, the irregularity of ventricular filling produces irregular intensity of S1, which is a key diagnostic feature. The integration of heart sound assessment with respiratory patterns, circulatory status, and autonomic tone provides a comprehensive approach to evaluating cardiac function in various clinical scenarios.

DefinitionHeart Sounds

S1: closure of atrioventricular valves; S2: closure of semilunar valves

Applied physiology and disorders

Heart sounds are intimately connected with the respiratory and circulatory systems, forming a crucial component of cardiovascular assessment. The first heart sound (S1) occurs at the beginning of systole and is produced by the closure of the atrioventricular valves—the tricuspid and mitral valves. This sound coincides with the QRS complex on an electrocardiogram and is best heard at the apex of the heart. The second heart sound (S2) occurs at the beginning of diastole and results from the closur

Abnormal heart sounds, or murmurs, result from turbulent blood flow caused by valvular abnormalities, structural defects, or other pathological conditions. Murmurs are characterized by their timing (systolic or diastolic), location, intensity, pitch, and quality. For example, a systolic murmur may indicate aortic stenosis, where the aortic valve fails to open fully, causing turbulent blood flow during ventricular contraction. The intensity of a murmur is graded on a scale of 1 to 6, with 1 being the faintest (heard only with careful auscultation) and 6 being the loudest (audible without a stethoscope). The timing of murmurs is crucial - systolic murmurs occur between S1 and S2, while diastolic murmurs occur between S2 and S1.

Extra heart sounds, S3 and S4, can provide additional diagnostic information. S3, known as a "ventricular gallop," occurs early in diastole. It is often associated with ventricular volume overload, such as in heart failure, dilated cardiomyopathy, or in conditions like mitral or aortic regurgitation. In children and young adults, an S3 may be physiological. S4, or "atrial gallop," occurs late in diastole, just before S1, and is typically associated with conditions that cause decreased ventricular compliance, such as hypertensive heart disease, hypertro [1]

In older adults, heart sounds may be diminished due to factors such as chest wall thickness, lung hyperinflation in COPD, or pericardial effusion. A paradoxical splitting of S2 can occur in right bundle branch block, aortic stenosis, or ventricular septal defect, where the pulmonary component of S2 is delayed. A fixed splitting of S2 is characteristic of atrial septal defect. In pregnancy, increased cardiac output and heart rate may alter the intensity and timing of heart sounds. In low-resource settings, where advanced imaging may not be available, careful auscultation of heart sounds remains a critical diagnostic tool for identifying valvular heart disease and other cardiac conditions.

Exam pearls

Clinical pearlHeart Sound Basics

The first heart sound (S1) is caused by closure of the atrioventricular valves (mitral and tricuspid) and marks the beginning of systole. [1]

Clinical pearlSecond Heart Sound

The second heart sound (S2) results from closure of the semilunar valves (aortic and pulmonary) and signifies the end of systole. [1]

Clinical pearlMitral Valve

The mitral valve (bicuspid valve) has two cusps attached to papillary muscles via chordae tendineae, preventing backflow into the left atrium during ventricular contraction. [1]

Clinical pearlValve Closure

Closure of atrioventricular valves prevents blood from being forced back into the atria during ventricular contraction. [1]

Exam trapS1 vs S2

S1 is louder at the apex (mitral area) while S2 is louder at the base (aortic and pulmonic areas) due to different valve positions and pressures.

Clinical pearlSplitting of S2

Normal physiological splitting of S2 occurs during inspiration due to increased venous return to the right heart, delaying pulmonic valve closure.

Exam trapParadoxical Splitting

Paradoxical splitting of S2 occurs when A2 is delayed (e.g., aortic stenosis, left bundle branch block), making S2 split during expiration and merge during inspiration.

Clinical pearlExtra Heart Sounds

S3 (ventricular gallop) occurs in early diastole and is normal in children but pathological in adults (e.g., heart failure). S4 (atrial gallop) occurs late in diastole and suggests atrial contraction against a stiff ventricle (e.g., hypertension, CAD).

NoteMurmurs

Murmurs result from turbulent blood flow across valves or through defects. Their timing (systolic/diastolic), location, and radiation help identify the underlying pathology.

Clinical pearlIntensity

S1 intensity decreases with mitral regurgitation (ventricular already partially filled) and increases with mitral stenosis (higher pressure needed to open stiff valve).

Clinical pearlA2 vs P2

A2 (aortic component of S2) is normally louder than P2 (pulmonic component) in adults due to higher pressures on the left side.

NoteDynamic Changes

Heart sounds can change with position (e.g., S1 louder in left lateral decubitus position in mitral stenosis) and respiration (e.g., split S2 in ASD).

Common pitfalls

Exam trapMisidentifying S1 and S2

The first heart sound (S1) is produced by closure of the atrioventricular valves (mitral and tricuspid), while the second heart sound (S2) results from closure of the semilunar valves (aortic and pulmonary). A common mistake is confusing these two sounds, particularly when the heart rate increases. S1 is typically louder and occurs at the beginning of systole, while S2 is shorter and higher-pitched, marking the beginning of diastole. [1]

Exam trapMissing split S2

A normal S2 may split physiologically during inspiration due to increased venous return to the right heart, delaying pulmonary valve closure. Students often fail to recognize this normal finding or mistake it for a pathological split. The split should be less than 30ms in normal individuals.

Exam trapOverlooking extra heart sounds

Third (S3) and fourth (S4) heart sounds are frequently missed or misinterpreted. S3 is a low-frequency sound heard in early diastole, often indicating volume overload or ventricular dysfunction, while S4 occurs just before S1 and suggests decreased ventricular compliance. These sounds are best heard with the bell of the stethoscope.

Exam trapIncorrect stethoscope placement

The pulmonary valve is located at the base of the pulmonary trunk. [1]

Exam trapMisinterpreting murmurs

Differentiating between systolic and diastolic murmurs is challenging for beginners. Systolic murmurs occur between S1 and S2, while diastolic murmurs occur between S2 and S1. The timing, pitch, and location of the murmur help identify its origin.

Exam trapIgnoring dynamic changes

Heart sounds change with respiration, position, and maneuvers like Valsalva. Students often fail to perform these maneuvers or interpret the resulting changes correctly. For example, murmurs of hypertrophic cardiomyopathy typically increase with Valsalva.

Where it is used in practice

DefinitionHeart sounds assessment

Heart sound auscultation is a fundamental clinical skill used to evaluate cardiac function and detect valvular abnormalities.

At the bedside, heart sound assessment is essential for diagnosing valvular heart disease. The characteristic sounds of stenotic or regurgitant valves help identify the specific valve affected and the severity of the pathology. For example, aortic stenosis produces a harsh systolic murmur radiating to the carotid arteries, while mitral regurgitation causes a holosystolic murmur at the apex.

In the operating theatre, heart sounds guide surgical decisions. During valve replacement or repair procedures, surgeons rely on intraoperative transesophageal echocardiography to visualize valve function, but auscultation provides complementary information. The disappearance of a murmur after valve repair confirms successful intervention.

Imaging modalities like echocardiography correlate heart sounds with structural findings. When an echocardiogram shows a prolapsing mitral valve, the corresponding mid-systolic click and late systolic murmur can be better understood. This integration of auscultation with imaging enhances diagnostic accuracy.

Heart Sound Assessment Approach

  1. Position patientSupine with slight left lateral tilt
  2. Systematic auscultationListen at all five valve areas
  3. Note timing and intensityS1, S2, extra sounds, murmurs
  4. Question: Abnormal findings?
    • Yes

      1. Characterize abnormalitiesTiming, location, radiation
      2. Perform maneuversRespiration, position, Valsalva
      3. Correlate with imagingEchocardiogram if indicated
    • No

      1. Document normal findingsRegular rate and rhythm
A systematic approach to heart sound evaluation.

In examinations, heart sound interpretation is a core competency. Objective structured clinical examinations (OSCEs) often include cardiac auscultation stations where students must identify normal and abnormal findings. Standardized patients with recorded heart sounds or mannequins with programmable sounds test this skill.

Clinical pearlBedside pearls

Additionally, having the patient lie on their left side may make S3 and S4 easier to hear. When documenting heart sounds, the carotid artery pulse can help differentiate S1 from S2 - the pulse coincides with S1. [1]

NoteDocumentation

When documenting heart sounds, be specific about the location, timing, intensity, and any abnormalities. For example: "S1 and S2 normal, no extra sounds, soft systolic murmur heard at left sternal edge radiating to apex". [1]

Key points

Heart sounds are produced by valve closure and blood flow S1 (AV valve closure) marks the beginning of systole S2 (semilunar valve closure) marks the beginning of diastole Extra heart sounds (S3, S4) indicate specific pathologies Auscultation requires systematic approach and proper technique Maneuvers like respiration and position change help identify murmurs Heart sound assessment integrates with imaging for diagnosis

Check yourself

Answer each one in your head first, then open the answer.

  1. What produces the first heart sound (S1)?

    Show answerHide answer
    Closure of the atrioventricular valves (mitral and tricuspid)
  2. What causes the second heart sound (S2)?

    Show answerHide answer
    Closure of the semilunar valves (aortic and pulmonary)
  3. Where is the pulmonary valve located for auscultation?

    Show answerHide answer
    At the base of the pulmonary trunk, requiring placement at the left second intercostal space
  4. What is a normal physiological split of S2 during inspiration?

    Show answerHide answer
    Less than 30ms
  5. Which heart sound is best heard with the bell of the stethoscope?

    Show answerHide answer
    Third (S3) and fourth (S4) heart sounds

References

  1. Betts JG, Young KA, Wise JA, et al. Heart Anatomy. OpenStax, Anatomy and Physiology 2e (CC BY-NC-SA 4.0). Accessed .

Figure credits

Educational content for medical students and doctors. It is not a substitute for clinical judgement or local guidelines.